A reliable system begins with the duty point.
The pump must deliver the required flow against the full resistance of the system. That operating target—flow rate at total dynamic head—is the duty point. Only after it is known should a pump model and photovoltaic array be selected.
Six steps to size a solar water pumping system
Calculate daily water demand
Add irrigation, livestock, domestic or process demand in cubic metres per day. Design for the highest realistic seasonal day, not the annual average.
Verify the source
Record static water level, pumping water level, borehole diameter and safe yield. A pump should never be sized to withdraw water faster than the source can recover.
Use the pumping water level—not only the resting level—when calculating lift.
Calculate total dynamic head
Combine vertical lift, drawdown, delivery elevation, required outlet pressure and pipe friction. Underestimating any part can leave the pump below its promised flow.
Set the design flow
Divide daily demand by realistic pumping hours. Use conservative peak-sun hours for the lowest-sun design month and allow for changing irradiance through the day.
Select pump and controller
Find a pump whose performance curve crosses the required flow and TDH with a sensible margin. Confirm motor voltage, controller limits and compatibility with the water source.
A motor power rating alone does not confirm water delivery.
Size the array and storage
Use the manufacturer's solar input requirements, local solar resource and temperature corrections. Water storage is often simpler and more durable than battery storage for daytime pumping.
Include mounting, cable sizing, earthing, surge protection, dry-run protection and level controls.
What goes into total dynamic head?
TDH is the total pressure the pump must overcome at the design flow. Measure each term in metres of water head and calculate friction at the intended flow rate.
Static lift
Vertical distance from pumping water level to the delivery point.
Drawdown
The additional fall in well level while the pump is operating.
Delivery & pressure
Elevation to the tank plus pressure required at the outlet or irrigation system.
Friction loss
Resistance through pipe, bends, valves and fittings; it rises rapidly with flow.
From daily demand to a pump duty point
Consider a farm that needs 30 m³ of water per day. The example is educational and is not a quotation or final system design.
- Daily demand: 30 m³/day
- Pumping water level: 42 m
- Tank elevation above wellhead: 8 m
- Pressure and friction allowance: 10 m
- Effective pumping window: 6 hours/day
The next step is to compare this duty point against manufacturer curves, then verify source yield and size the array for the chosen pump/controller combination.
Choose by the duty point—not by habit.
Centrifugal
Common for moderate-to-high flows. Multi-stage submersible models can serve deeper boreholes, while surface models suit accessible sources within suction limits.
Often suited to irrigation and higher daily volumes.
Positive displacement
Moves a fixed volume each cycle and can perform efficiently at lower flows and higher heads. Water quality and maintenance access still matter.
Often suited to deep wells with modest flow demand.
What determines solar water pump cost?
There is no useful one-price answer without a duty point and site survey. These factors shape the installed budget:
Hydraulic duty
Higher flow and TDH generally require a larger pump, controller and PV array.
Well and source
Borehole depth, diameter, water quality, yield testing and pump installation affect equipment and labour.
Solar array
Module capacity, mounting structure, wind loading, cable routes and security all influence cost.
Pipe and storage
Pipe diameter and length, valves, fittings, tank volume and civil works can be significant.
Controls and protection
Dry-run, tank-level, surge, earthing, monitoring and backup requirements change the system scope.
Site conditions
Access, terrain, transport, trenching and commissioning requirements affect installation effort.
Common sizing mistakes
- Sizing from pump horsepower alone
- Using static water level instead of pumping level
- Ignoring pipe friction and outlet pressure
- Assuming every daylight hour is a full-power pumping hour
- Oversizing withdrawal beyond the source's safe yield
- Buying components before checking a complete pump curve
- Skipping dry-run, surge and level protection
Information your solar engineer will need
Solar pumping glossary
- TDH
- Total dynamic head: the complete pressure the pump must overcome.
- Duty point
- The required combination of flow rate and head.
- Static water level
- Water depth when the well is resting.
- Pumping water level
- Water depth while pumping at a stated rate.
- Peak-sun hour
- Solar energy equivalent to one hour at 1,000 W/m²; not simply one daylight hour.
- Pump curve
- Manufacturer data showing pump performance across flow and head.
Turn site measurements into a dependable water supply.
CEW can assess the source, calculate the duty point, select matched equipment and plan installation for your site in Yemen.