Solar panels powering a water pumping project
Field guide · Yemen

Solar water pump sizing and cost, explained.

A practical path from daily water demand and well depth to the right pump, solar array, storage plan and realistic project budget.

Start with water, not watts

A reliable system begins with the duty point.

The pump must deliver the required flow against the full resistance of the system. That operating target—flow rate at total dynamic head—is the duty point. Only after it is known should a pump model and photovoltaic array be selected.

This guide supports early planning. Final design requires verified site measurements, a water-source yield test and the selected manufacturer's pump curves.

Six steps to size a solar water pumping system

01

Calculate daily water demand

Add irrigation, livestock, domestic or process demand in cubic metres per day. Design for the highest realistic seasonal day, not the annual average.

Daily demand = users or area × daily allowance
02

Verify the source

Record static water level, pumping water level, borehole diameter and safe yield. A pump should never be sized to withdraw water faster than the source can recover.

Use the pumping water level—not only the resting level—when calculating lift.

03

Calculate total dynamic head

Combine vertical lift, drawdown, delivery elevation, required outlet pressure and pipe friction. Underestimating any part can leave the pump below its promised flow.

TDH = static lift + drawdown + delivery head + pressure head + friction loss
04

Set the design flow

Divide daily demand by realistic pumping hours. Use conservative peak-sun hours for the lowest-sun design month and allow for changing irradiance through the day.

Design flow (m³/h) = daily demand (m³) ÷ effective pumping hours
05

Select pump and controller

Find a pump whose performance curve crosses the required flow and TDH with a sensible margin. Confirm motor voltage, controller limits and compatibility with the water source.

A motor power rating alone does not confirm water delivery.

06

Size the array and storage

Use the manufacturer's solar input requirements, local solar resource and temperature corrections. Water storage is often simpler and more durable than battery storage for daytime pumping.

Include mounting, cable sizing, earthing, surge protection, dry-run protection and level controls.

The critical calculation

What goes into total dynamic head?

TDH is the total pressure the pump must overcome at the design flow. Measure each term in metres of water head and calculate friction at the intended flow rate.

1

Static lift

Vertical distance from pumping water level to the delivery point.

2

Drawdown

The additional fall in well level while the pump is operating.

3

Delivery & pressure

Elevation to the tank plus pressure required at the outlet or irrigation system.

4

Friction loss

Resistance through pipe, bends, valves and fittings; it rises rapidly with flow.

Illustrative example

From daily demand to a pump duty point

Consider a farm that needs 30 m³ of water per day. The example is educational and is not a quotation or final system design.

  • Daily demand: 30 m³/day
  • Pumping water level: 42 m
  • Tank elevation above wellhead: 8 m
  • Pressure and friction allowance: 10 m
  • Effective pumping window: 6 hours/day
Total dynamic head: 42 + 8 + 10 = 60 m
Design flow: 30 ÷ 6 = 5 m³/h
Duty point to verify: 5 m³/h at 60 m TDH

The next step is to compare this duty point against manufacturer curves, then verify source yield and size the array for the chosen pump/controller combination.

Pump selection

Choose by the duty point—not by habit.

Centrifugal

Common for moderate-to-high flows. Multi-stage submersible models can serve deeper boreholes, while surface models suit accessible sources within suction limits.

Often suited to irrigation and higher daily volumes.

Positive displacement

Moves a fixed volume each cycle and can perform efficiently at lower flows and higher heads. Water quality and maintenance access still matter.

Often suited to deep wells with modest flow demand.

Budget planning

What determines solar water pump cost?

There is no useful one-price answer without a duty point and site survey. These factors shape the installed budget:

Hydraulic duty

Higher flow and TDH generally require a larger pump, controller and PV array.

Well and source

Borehole depth, diameter, water quality, yield testing and pump installation affect equipment and labour.

Solar array

Module capacity, mounting structure, wind loading, cable routes and security all influence cost.

Pipe and storage

Pipe diameter and length, valves, fittings, tank volume and civil works can be significant.

Controls and protection

Dry-run, tank-level, surge, earthing, monitoring and backup requirements change the system scope.

Site conditions

Access, terrain, transport, trenching and commissioning requirements affect installation effort.

Compare proposals at the same flow and TDH. A cheaper pump quoted at a different duty point is not an equivalent system.
Avoid underperformance

Common sizing mistakes

  • Sizing from pump horsepower alone
  • Using static water level instead of pumping level
  • Ignoring pipe friction and outlet pressure
  • Assuming every daylight hour is a full-power pumping hour
  • Oversizing withdrawal beyond the source's safe yield
  • Buying components before checking a complete pump curve
  • Skipping dry-run, surge and level protection
Prepare for assessment

Information your solar engineer will need

Site coordinates and intended use
Daily and peak-season water demand
Source type and borehole diameter
Static and pumping water levels
Recent yield-test information
Delivery elevation and pipe route length
Required outlet pressure
Tank capacity and location
Water quality or solids concerns
Photos of the source, route and array area
Quick reference

Solar pumping glossary

TDH
Total dynamic head: the complete pressure the pump must overcome.
Duty point
The required combination of flow rate and head.
Static water level
Water depth when the well is resting.
Pumping water level
Water depth while pumping at a stated rate.
Peak-sun hour
Solar energy equivalent to one hour at 1,000 W/m²; not simply one daylight hour.
Pump curve
Manufacturer data showing pump performance across flow and head.
Engineer the whole system

Turn site measurements into a dependable water supply.

CEW can assess the source, calculate the duty point, select matched equipment and plan installation for your site in Yemen.